Indium Corporation
From One Engineer to Another®

Flux Evaluation for AuSn High Temperature Solder Reflow

Monday, June 6, 2011 by Amanda Hartnett [Amanda Hartnett]

High Temperature reflow profile for flux testing with AuSn, AuGe, or AuSiRecent test results show that solder fluxes handle high reflow temperatures (>450°C), providing better-than-expected visual results of flux residue!  

Solder fluxes have not traditionally been used with AuSn, AuGe, or AuSi eutectic solder, because their peak reflow temperatures were very close to or above the flux activation range. An average flux activates at approximately 125°C and is not recommended for temperatures in excess of 350°C. Although AuSn solder melts at 280°C, peak reflow temperatures are recommended to be >300°C, nearing the maximum suggested temperature of flux. AuGe and AuSi alloys melt at 356°C and 363°C respectively, which exceed the documented flux activation range.

AuSn solder preform tested with flux for braze temperature reflow AuGe AuSi.  Poor flux selection result.Since these alloys contain ≥80% gold and are resistant to oxidation, flux is not always necessary. Other methods have conventionally replaced the flux function, such as mechanical scrubbing, or forming gas purging. If these technologies are not available, or assembly speed is priority though, a flux may be required.



So I, along with my fellow engineer, Brandon Judd, sought out to test some of our best fluxes with Au alloys at these high temperatures. The result: Not all, but a few of these fluxes work extremely well up to temperatures as high as 450°C!!!

The reflow profiles used tested the extreme abilities of our fluxes:

·         Peak temperature 410°C

·         Nitrogen Purge

·         AuSn preform for testing high temperature braze reflow AuGe AuSi.  Indium Corporation's TacFlux010 good flux selection for high temperature reflow.Time above liquidus: 137 seconds

·         80AuSn solder preforms 0.249” square x 0.002”

Some fluxes did what we expected- they charred and burned. They simply were not designed for this environment. 

Others, such as our TacFlux010® were very resilient at these temperatures. 

For more information about these test results, please contact myself or Brandon.

Happy Testing!!

Amanda

 

 

 


Comments for Flux Evaluation for AuSn High Temperature Solder Reflow

Tuesday, August 30, 2011 by samorn:
Dear Sir,
am Samorn Paha take care mat'l control at HANA SEMICONDUCT ( BKK)
I'm looking high temp >350c , May you recomment on that. and send us the qoute.
Tuesday, October 25, 2011 by zhixiong xiao:
I hope to buy the flux and high T solder, which can work at 350C. Ausn, Ausi or AuGe are all okay for me.

Please give me a recommendation.

Best regards

Zhixiong Xiao

4087393533 ext 229
Sunday, December 11, 2011 by Pony Liao:
Hi Amanda, so no formic acid needed for reflow with TacFlux010?
Monday, December 12, 2011 by Amanda Hartnett:
Pony,

When soldering with such high temperature alloys, and especially when using flux vehicles such as TacFlux010 which have low solids content (Purposefully to leave very low residue), it is absolutely necessary to purge the atmospheric oxygen during reflow. This can be done using numerous types of inert gases, however pure nitrogen is most common. Formic Acid will have the same effect, however the hydrogen addition is not necessary when a flux is used.